• Professional Pre-sale Service

    1. Filtration method and equipment recommendation.
    2. Free CAD or 3D drawing.
    3. Equipment can be customized.
  • Complete Service During Sales

    1. On-time delivery.
    2. Equipment inspection by photo or video.
    3. Secure and standard package.
  • After-Sale Service

    1. Installation assistance by a phone call or video.
    2. Free accessories for maintenance.
    3. Engineer sent to solve the onsite problem.
Skip to product information
1 of 5

Two-Stage RO and EDI System

Material

Respond to your needs within 10 minutes.
ASME/ CE/ TUV/ SGS/ BV Certification

Regular price $25,000.00
Regular price $25,600.00 Sale price $25,000.00
Sale Sold out
Shipping calculated at checkout.
Contact us to Get Special Prices for you!
Book time with Kris: Teams Online Meeting-JX Filtration 

Optimized Typical Process Flow

Raw Water → Raw Water Tank (304 Stainless Steel, with Level Interlock Control) → Booster Pump (Grundfos CR Series) → Multimedia Filtration → Activated Carbon Adsorption → Water Softening → Precision Filter (5 μm PP Cartridge) → High-Pressure Pump (Multistage Centrifugal) → RO Membrane Rack → Pure Water Tank → UV Sterilization → EDI (Electrodeionization) for Deep Desalination → 18.2 MΩ·cm Ultra-Pure Water


Industry Application Examples

Aerospace Sector
The International Space Station utilizes RO technology to achieve an 85% urine recovery rate, saving approximately CNY 320,000 per ton of water daily.

Electronics Industry
A semiconductor manufacturing plant implemented a two-stage RO + EDI system, producing 18.2 MΩ·cm resistivity ultra-pure water, resulting in a 2.3% increase in wafer yield.

Medical Field
Dialysis water treated via RO achieves an endotoxin level of <0.03 EU/mL, fully compliant with YY0572-2015 standards.


Key Points for Operation & Maintenance

  1. Fouling Index Control

    • SDI15 must be consistently <3

    • Membrane flux should be maintained at 22–28 GFD (for standard water sources)

  2. Chemical Cleaning Protocols

    • pH 2 Citric Acid for inorganic scale removal

    • pH 12 Sodium Hypochlorite + EDTA for biofilm removal