Raw Water โ Raw Water Tank (304 Stainless Steel, with Level Interlock Control) โ Booster Pump (Grundfos CR Series) โ Multimedia Filtration โ Activated Carbon Adsorption โ Water Softening โ Precision Filter (5 ฮผm PP Cartridge) โ High-Pressure Pump (Multistage Centrifugal) โ RO Membrane Rack โ Pure Water Tank โ UV Sterilization โ EDI (Electrodeionization) for Deep Desalination โ 18.2 Mฮฉยทcm Ultra-Pure Water
Industry Application Examples
Aerospace Sector The International Space Station utilizes RO technology to achieve an 85% urine recovery rate, saving approximately CNY 320,000 per ton of water daily.
Electronics Industry A semiconductor manufacturing plant implemented a two-stage RO + EDI system, producing 18.2 Mฮฉยทcm resistivity ultra-pure water, resulting in a 2.3% increase in wafer yield.
Medical Field Dialysis water treated via RO achieves an endotoxin level of <0.03 EU/mL, fully compliant with YY0572-2015 standards.
Key Points for Operation & Maintenance
Fouling Index Control
SDI15 must be consistently <3
Membrane flux should be maintained at 22โ28 GFD (for standard water sources)
Chemical Cleaning Protocols
pH 2 Citric Acid for inorganic scale removal
pH 12 Sodium Hypochlorite + EDTA for biofilm removal
Our Certificates
Business License
CE
TUV
BV
SGS
Trademark Certificate
Export License
Customs License